TensorNodeStart free trial
Home / Products / Drainage / Stormwater Detention

Stormwater Detention calculator for AS/NZS 3500 and EN 752

On-site stormwater detention (OSD).

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The pre- and post-development peak flows, the required detention storage volume and the orifice size to throttle the outflow to the permitted site-discharge.

Inputs

Stormwater Detention takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Catchment
Catchment aream²500
Pre-dev runoff C-0.4
Post-dev runoff C-0.9
Rainfall
Rain intensity imm/hr120
Critical durationmin20
Outlet
Permitted discharge (0=use pre)L/s0
Orifice headm1
Orifice Cd-0.6

Results and report

The module reports: Pre-dev peak Qpre; Post-dev peak Qpost; Permitted discharge; Required storage; Orifice diameter.

It checks: Pre/post peak flow; Required storage; Orifice diameter.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Stormwater Detention with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Catchment area500 m²
Pre-dev runoff C0.4
Post-dev runoff C0.9
Rain intensity i120 mm/hr
Critical duration20 min
Permitted discharge (0=use pre)0 L/s
Orifice head1 m
Orifice Cd0.6

Headline results:

ResultValue
Pre-dev peak Qpre6.7 L/s
Post-dev peak Qpost15.0 L/s
Permitted discharge6.7 L/s
Required storage10.0 m³
Orifice diameter57 mm

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Stormwater Detention works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS/NZS 3500
United StatesModified rational method / local authority
CanadaModified rational method / municipal criteria
EuropeEN 752

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Drainage
    Pipe / drain capacity by the Manning equation
  • Rainfall Intensity (AEP)
    Design rainfall intensity expressed in the modern annual-exceedance-probability (AEP) frequency descriptor
  • Rainfall Intensity (ARI)
    Design rainfall intensity for a chosen average recurrence interval (ARI) and storm duration from the site IFD coefficients, with the equivalent AEP and an optional Rational-Method peak flow.

All modules

Open Stormwater Detention with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.