What it checks
The pre- and post-development peak flows, the required detention storage volume and the orifice size to throttle the outflow to the permitted site-discharge.
Inputs
Stormwater Detention takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Catchment | ||
| Catchment area | m² | 500 |
| Pre-dev runoff C | - | 0.4 |
| Post-dev runoff C | - | 0.9 |
| Rainfall | ||
| Rain intensity i | mm/hr | 120 |
| Critical duration | min | 20 |
| Outlet | ||
| Permitted discharge (0=use pre) | L/s | 0 |
| Orifice head | m | 1 |
| Orifice Cd | - | 0.6 |
Results and report
The module reports: Pre-dev peak Qpre; Post-dev peak Qpost; Permitted discharge; Required storage; Orifice diameter.
It checks: Pre/post peak flow; Required storage; Orifice diameter.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Stormwater Detention with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Catchment area | 500 m² |
| Pre-dev runoff C | 0.4 |
| Post-dev runoff C | 0.9 |
| Rain intensity i | 120 mm/hr |
| Critical duration | 20 min |
| Permitted discharge (0=use pre) | 0 L/s |
| Orifice head | 1 m |
| Orifice Cd | 0.6 |
Headline results:
| Result | Value |
|---|---|
| Pre-dev peak Qpre | 6.7 L/s |
| Post-dev peak Qpost | 15.0 L/s |
| Permitted discharge | 6.7 L/s |
| Required storage | 10.0 m³ |
| Orifice diameter | 57 mm |
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Stormwater Detention works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS/NZS 3500 |
| United States | Modified rational method / local authority |
| Canada | Modified rational method / municipal criteria |
| Europe | EN 752 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Drainage
Pipe / drain capacity by the Manning equation - Rainfall Intensity (AEP)
Design rainfall intensity expressed in the modern annual-exceedance-probability (AEP) frequency descriptor - Rainfall Intensity (ARI)
Design rainfall intensity for a chosen average recurrence interval (ARI) and storm duration from the site IFD coefficients, with the equivalent AEP and an optional Rational-Method peak flow.
Open Stormwater Detention with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.