TensorNodeStart free trial
Home / Features / Strut-and-tie

Strut-and-tie design with the elastic stress field drawn underneath

Deep beams, corbels and other D-regions do not follow plane sections, so a fibre section does not describe them. TensorNode designs them with a strut-and-tie model and draws that model over a linear-elastic plane-stress analysis of the region, the way the method is taught and laid out.

A deep beam D-region with principal stress trajectories in blue and red and the strut-and-tie model of the module drawn on top

The stress field under the model

The region is meshed with four-node plane-stress elements and solved. The drawing shows the principal stress trajectories (compression in blue, tension in red), a contour of the chosen stress, and the module's own struts, ties and nodes on top. This follows the practice that the elastic stress field guides the strut-and-tie layout (Schlaich, Schafer and Jennewein, PCI Journal 1987; fib Bulletin 45, 2008; ACI 318-25 R23.2). The stresses are elastic, before cracking: once the tension exceeds fct the concrete cracks and the ties carry the tension, which is what the code check designs.

What the module checks

  • The strut efficiency factor βs of the code and the capacity of the diagonal strut.
  • The tie force, the tie reinforcement (bar diameter and number) and its anchorage.
  • Node bearing and the diagonal compression limit.
  • The bursting reinforcement of a bottle-shaped strut.

The width of the strut at the bottom node comes from the bearing length and the node depth:

ws=lbsin⁡θ+ubcos⁡θw_s = l_b \sin\theta + u_b \cos\theta

Example with the default inputs (AS 3600)

A member 800 mm deep and 400 mm wide, load 0.8 m from the support, bearing width 300 mm, f'c 40 MPa, fsy 500 MPa, P* = 400 kN, six N20 tie bars. The engine finds a strut angle of 40.2 degrees, βs = 0.519, a strut force of 620 kN against a strut capacity of 1311 kN, and a tie force of 474 kN needing 1115 mm² against 1885 mm² provided. The governing check is the bursting reinforcement of the strut at serviceability, utilisation 0.95, which passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Related modules

  • Strut & Tie
    Strut-and-tie model for a concrete D-region / deep beam to AS 3600 §7
  • Deep Beam
    RC deep beam (span/depth < 2) by strut-and-tie to AS 3600 §7
  • Corbel / Bracket
    Reinforced-concrete corbel / bracket to AS 3600

More

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.